| | TRP-C37M You are here: The Debug Store > Automation > Automation Interfaces > ModBus > Trycom > TRP-C37M | * Wide input range DC power supply. * Built-In watchdog function prevents system boot fail. * Support Auto-MDIX twisted pair crossover detection and Auto-Correction. * Modbus Type support TCP Master to Serial Slave and TCP Slave to Serial Master. * Support 1 serial master to 8 TCP slave ,each TCP slave can free set up UID from 0~256.. * Compatible with Modscan32 ,Modbus Poll,CAS Modbus Scanner and SCADA .. application. * Support virtual com maximum connection 16 client. * Auto fast direction RS-485 flow control by hardware. * Surge protection and over current and over voltage on RS-422/485 data lines. * Support baud rate from1200~921600Kbps. * Auto switching RS-232C/RS-422/RS-485 signal interface. * Fully compatible with Ethernet and TCP/IP protocol. * Supports 10/100 Mbps Ethernet. * Power/Link/UART RX/UART TX mode LED indicator. * Heart Beat function ensures a reliable communicating connection. * Auto reconnection when power or Ethernet fail. * Back to factory configuration by external switch. * Support configuration by serial console. * Update the firmware from LAN. * Dual power input select from screw terminal or DC-Jack.
|
| * Power Input Voltage: DC +10V to +30V. * LAN: Auto-MDIX, 10/100 Mbps Auto-detecting. * RS-232: TX, RX, RTS, CTS, DTR, DSR, DCD, GND. * RS485 signal: differential 2 half-duplex wires (DATA+, DATA-). * RS422 signal: differential 4 full-duplex wires.(TX+,RX+,TX-,RX-) * Baud Rate: 1200,2400,4800,9600,19200,38400,57600,115200,921600 K bps. * Parity: none, even, odd. * Data Bits: 5, 6, 7 or 8. * Stop Bits: 1, 1.5 or 2. * Modbus TCP Type: TCP Master to Serial Slave, TCP Slave to Serial Master. * TCP Slave to Serial Master Mode: Maximum 8 TCP Port. UID Range:00~FF. * Virtual-com driver support Windows 98/2000/2003 and WIN7. * External switch: OFF OFF : Directly IP mode, RTU protocol. . ON OFF : Virtual-Com and Paired mode . OFF ON : Directly IP mode, ASCII protocol ON ON : Back to Factory. * Virtual-Com mode support RS232 TXD,RXD,GND. RS422 TX+,TX-,RX+,RX-. RS485 D+,D-. * Power supply: Screw terminal, or DC jack. * Serial interface: +/-15 KV ESD. * RS422/485 interface: Surge, over current, over voltage protection. * RS422/485 interface: Industrial plug-in screw terminal. * Plug-in screw terminal wiring: Accepts AWG #12 ~30 wires. * Power consumption: 12V/140mA. * Operating Temperature: -10 to 65 °C. * Humidity: 0~90% Non-Condensing. * Dimensions: 151(L)*75(W)*26(H) mm. * Weight: 395g with packing. |
|
You are here: The Debug Store > Automation > Automation Interfaces > ModBus > Trycom > TRP-C37M |

 

|